©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 10 eI/O modules are powered in one of two ways  9-30 V DC power inputs  802.3af-2003 Powe

Pagina 3

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 11 eI/O-110 modules provide 4 optically isolated inputs and 4 Form A Reed Relay outputs. Input

Pagina 4

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 12 The eI/O-120 provides 4 optically isolated inputs and 4 SPDT Form C relay outputs. Inputs

Pagina 5

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 13 eI/O-130 modules provide 4 optically isolated inputs with 2500VAC RMS / 3500VDC external is

Pagina 6

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 14 The eI/O-140 provides 4 SPST Form A dry-contact Form A Reed Relays. Form A Reed Relays offe

Pagina 7

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 15 The eI/O-150 provides 4 optically isolated inputs and 4 SPDT Form C relay outputs. Inputs c

Pagina 8

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 16 eI/O standard units are powered from a 9-30VDC source using the screw terminals on the side

Pagina 9 - SL9049 - 03/2011

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 17 The SeaMAX Suite is a collection of configuration/diagnostic utilities and software librari

Pagina 10

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 18 Proceed with installing the SeaMAX Software Suite using the software disk that was included

Pagina 11

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 19 5. Type the part number for your adapter in the text box and click „Enter‟, or click on th

Pagina 12

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 2 Before You Get Started ...

Pagina 13

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 20 1. To install the driver executable from the Sealevel disk, browse the Sealevel Systems di

Pagina 14

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 21 4. In the Device Manager under „Action‟, choose „Scan for hardware changes‟. This will pro

Pagina 15

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 22 Once the host computer is configured correctly, the “SeaI/O Configuration” tab becomes avai

Pagina 16

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 23 After the Get command is executed, the “Module Description” frame will display the model ty

Pagina 17

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 24 The „Digital IO‟ tab of MaxSSD is displayed when using Sealevel I/O devices featuring discr

Pagina 18

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 25 Following these simple steps can eliminate most common problems. 1. Read this manual thor

Pagina 19

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 26 Problem: The eI/O module starts up with a strange IP address (i.e., 192.168.42.253). All

Pagina 20

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 27 Verify that SeaMAX software has been installed successfully and that an eI/O module is conn

Pagina 21

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 28 An eI/O module may become no longer visible in the module list in the Ethernet Config utili

Pagina 22

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 29 Modules with version “2” or higher support several Advanced Features. You may determine th

Pagina 23

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 3 Warranty ...

Pagina 24

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 30 Type Cd “C:\Program Files\Sealevel Systems\SeaMAX\” and then press Enter When the comm

Pagina 25

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 31 Once the proper file has been selected, click on the “Flash Firmware” button. At this po

Pagina 26

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 32 Optically isolated inputs are arranged such that each pair shares a single common. The four

Pagina 27

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 33 eI/O Ethernet connector is used for both data and power in the PoE series of modules. Both

Pagina 28

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 34 eI/O modules ship ready for mounting on DIN rail. A small, rugged plastic (shown below) is

Pagina 29

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 35 A sudden electrostatic discharge can destroy sensitive components. Proper packaging and gro

Pagina 30

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 36 When calling for technical assistance, please have the device installed and ready to run di

Pagina 31

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 37 Sealevel's commitment to providing the best I/O solutions is reflected in the Lifetime

Pagina 32

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 4 All eI/O modules are shipped with the following items. If any of these items is missing or d

Pagina 33

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 5 Sealevel eI/O™ modules offer powerful data acquisition solutions that are perfect for a wide

Pagina 34

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 6 Ethernet 10/100 BaseT eI/O 110E – 4 Optically Isolated Inputs/4 Form A Reed Relay Output

Pagina 35

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 7 Depending on the interface type, your eI/O module may include additional accessories. Includ

Pagina 36

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 8 100-240VAC to 24VDC @ 2.1A DIN Rail Power Supply (Part# PS103) The PS103 is an AC/DC DIN rai

Pagina 37

©Sealevel Systems, Inc. SL9049 - 03/2011 eI/O Manual 9 CAT5 Patch Cable, 10' in Length (Part# CA247) 10‟ Blue Ethernet Patch Cable. Can be